TDKL CUS350M convection cooled power supplies are ideal for applications where acoustical noise cannot be tolerated

Convection cooled power supplies are ideal for applications where acoustical noise cannot be tolerated or when there is a possibility that dirt, dust and other materials can be drawn in by a cooling fan. With power supply efficiencies now commonly in excess of 90%, more fan-less products are entering the market, particularly in the 100 to 300W power range.

At first glance it seems that they are easier to install.No need to direct forced air at the power supply or calculate how much air is needed – the product will operate correctly without any concern.There are, however, some considerations that the user should be aware of.

The definition of convection cooling is the transfer of heat by the movement of fluids or gas.Hot air rises, being less dense than cold air, causing the circulation of air through or around a heat dissipating product.

In the case of an open frame power supply, it is often mounted horizontally on standoffs to provide clearance for solder joints and under board components.Figure 1 shows the direction of the air currents, with the cooler air being drawn in at the bottom.

The speed of this air is quite low, in the order of 0.3m/s, but it is enough to reduce the power supply’s component temperatures and avoid ‘hot spots’.The safety bodies (BSI, TUV, UL, etc) perform thermal testing in this orientation and state on the conditions of acceptability that thermal measurements should be repeated in the end equipment.

To avoid restricting the natural convection air currents, sufficient clearance should be provided around the power supply.A 50mm space is considered adequate.

In some applications a vertical orientation is required (figure 2) and care should be taken to examine if heatsinks and other bulky parts will restrict the air currents.To increase field life it is good practice to ensure that electrolytic capacitors are situated at the bottom where they will operate cooler.

Often manufacturers will state a recommended mounting orientation and suggest a derating factor if that is not possible.Mounting a convection cooled power supply upside down (with the circuit board at the top – Figure 3) can dramatically reduce field life.This is usually forbidden.

If you have concerns, consult the manufacturer’s installation manual, or contact their technical support.With high density power supplies, there is usually a list of maximum component temperatures for the critical parts.To avoid potential delays during safety certification, it is best to check those before submitting your product.

Author
TDK-Lambda UK

Comment on this article


This material is protected by MA Business copyright See Terms and Conditions. One-off usage is permitted but bulk copying is not. For multiple copies contact the sales team.

What you think about this article:


Add your comments

Name
 
Email
 
Comments
 

Your comments/feedback may be edited prior to publishing. Not all entries will be published.
Please view our Terms and Conditions before leaving a comment.

Related Articles

Solution Simulator

ROHM has added a new thermal analysis function to its Solution Simulator.

ATEasy 2021 released

Marvin Test Solutions, a provider of test solutions for military, aerospace, ...

Early detection

A length-unlimited flexible printed circuit technology is enabling a robust, ...

Smart construction

For an industry that accounts for 6% GDP worldwide, construction players have ...

InnoSwitch3-TN ICs

Power Integrations has introduced the highly integrated InnoSwitch3-TN ...

Get to market faster

A quick look at using Vicor's PFM and AIM in VIA packaging for your AC to Point ...

Digital consciousness

​Would you consider uploading your brain to the cloud if it meant you could ...

Improving cancer care

Mirada Medical’s imaging technology is helping to accelerate cancer care by ...