10 May 2010

The changing face of emi compliance

  • System design

The implications of CISPR 16-1-1's recent update to include spectrum analysers for emi compliance measurement.

The world of electromagnetic interference (emi) measurement is undergoing a rethink, thanks to the release by the International Electrotechnical Commission of Edition 3 of the CISPR 16-1-1 standard; otherwise known as CISPR 16-1-1:2010.

CISPR 16-1-1 specifies the characteristics and performance of equipment for measuring radio disturbance in the 9kHz to 18GHz frequency range, as well as providing requirements for specialised equipment for discontinuous disturbance measurements. The reason for the rethink is that the 2010 version of this standard now allows spectrum analysers to be used to test emi, in addition to dedicated, but more costly, emi receivers.

Any change in CISPR 16-1-1 has an impact on how all types of electronic equipment are tested in Europe, as CISPR 16-1-1 defines the measurement apparatus, measurement methods, measurement uncertainty and test facilities used by all electrical product groups. So, whilst the addition of spectrum analysers to the apparatus one can use for testing emi might not sound of great consequence, it has the potential to change the way in which every single electrical product is tested in the future. Indeed, radio and tv receivers (covered by Edition 4 of CISPR 13) are the first product group to adopt CISPR 16-1-1:2010 and it will come into force for other types of equipment in the following months to years, depending upon the next review date of individual product standards.

It is worth noting that whilst CISPR 16-1-1 is an international standard, it covers primarily European emi emissions measurement, with similar regulations in force on other continents. In the US, the equivalent standard for emc emissions measurement is ANSI 63.2 (the American National Standard for Electromagnetic Noise and Field Strength Instrumentation, 10Hz to 40GHz), where spectrum analysers have always been used for emission compliance measurement.

With the world of interference changing all the time, emi measurement standard updates tend to reflect new detector developments or new broadband technologies. But, as in the case of CISPR 16-1-1:2010, closer alignment with the US standard is likely to have played a part in the adoption of spectrum analysers for emi measurement. Another catalyst is the potential cost saving to end users, thanks to general purpose spectrum analysers being much cheaper than dedicated emi test receivers.

However, there is a temptation to believe that any spectrum analyser can be used to make emi compliance measurements and this is not the case. CISPR 16-1-1:2010 allows spectrum analysers without preselection filters to be used for such measurements in some limited conditions – not all.
Although the spectrum analyser does not need a preselector, CISPR 16-1-1 still requires some very specific functions that are not generally incorporated in a general purpose spectrum analyser's feature set just yet. These include a quasi peak detector that is capable of measuring pulsed signals with repetition frequency equal to or exceeding 20 pulses per second. In addition, a linear average detector with meter time constant (used to simulate a critically damped indicating instrument) is necessary order to detect intermittent, unsteady or drifting narrowband disturbances. Meanwhile, it has been suggested that a spectrum analyser used for emi measurements has 6dB bandwidths of 200Hz, 9kHz, 120kHz and an impulse bandwidth of 1MHz. Alternative emission measurements with 100Hz, 10kHz and 100kHz bandwidth are acceptable, as long as the results are not ambiguous. It is possible to use a different bandwidth and compensate by applying a margin of error.

So, when can a spectrum analyser without preselection be used? A spectrum analyser without preselection adds a level of uncertainty to the test procedure, so it really is only possible to test emi in this scenario if the disturbance characteristics are known; for example, with something like a television, where the characteristics of all sources of disturbance are well defined. A spectrum analyser without pre-selection can be used when the device under test does not repeat pulsed disturbance at a frequency of less than 20Hz.

Another scenario is when the difference in amplitude between the peak and quasi peak signals does not exceed defined values. Again, with a tv, there's little likelihood of the difference exceeding the source values, but for products such as household appliances, electric tools and automotive components, the difference cannot be known. Notably, with high amplitude or broadband signals, a spectrum analyser without preselection is vulnerable to overloading the front end. It is advised that when measuring low level spurious signals in the presence of a strong fundamental signal, a filter is inserted at the measuring receiver's input, to provide adequate attenuation at the fundamental frequency to protect the input circuits of the receiver from overload or damage.

For users who plan to carry out emi precompliance testing using a spectrum analyser, it is worth bearing in mind that the results of tests on the disturbance characteristics may not show the necessary precision, so that the quasi peak measurement will need to be repeated with a fully compliant measuring receiver in order to achieve a valid outcome. A validation procedure is described in CISPR 16-2 that enables test engineers to determine the suitability of an instrument to emi compliance.

As with all new standards, there will be a transition period to ensure there is time for people to fully adjust to the new changes. This is likely to mean that whilst few spectrum analysers yet boast quasi peak or linear average detectors, or the bandwidths mentioned earlier, these features may become more common over time as test manufacturers react to the demands of this new legislation. Both Rohde & Schwarz' range of compliance and precompliance instruments meet the latest requirements of CISPR 16-1-1, with the precompliance units including all the detectors and filters necessary.

What remains critical for this industry is that emi emissions measurement is in no way 'watered down' by changing regulation. This is unlikely to be the case, but with emi having been the subject of more column inches of late than might be expected from something so tightly monitored, changes to CISPR must not compromise the rigour of emi testing. One source of many of the most recent mentions was Toyota's mass recall of models with faulty accelerator pedals. Though the company has insisted the problems are purely mechanical, electrical issues – emi in particular – have been implicated as a cause of some of the fault conditions. EMI testing may have just become slightly cheaper, but certainly no easier.

Author profile:
Andy Coombes is emc product manager for Rohde & Schwarz.

Author
Andy Coombes

Supporting Information

Downloads
24879\The_changing_face_of_emi_compliance.pdf

Websites
http://www.rohde-schwarz.co.uk/

Companies
Rohde & Schwarz (UK) Ltd

This material is protected by Findlay Media copyright
See Terms and Conditions.
One-off usage is permitted but bulk copying is not.
For multiple copies contact the sales team.

Do you have any comments about this article?

Add your comments

Name
 
Email
 
Comments
 

Your comments/feedback may be edited prior to publishing. Not all entries will be published.
Please view our Terms and Conditions before leaving a comment.

 

Related Articles

'Electronic nose' created

UK firm Peratech has created an 'electronic nose' that detects the presence of ...

pMEMS oscillators world first

IDT has launched what it claims to be the world's first crystal free ...

Baolab to create smart IMUs

Baolab Microsystems plans to modify the structures of its 3D NanoCompass to ...

Testing, testing

When thinking about product testing, most people focus on the area of most ...

Setting the standard

Just a stone's throw away from the River Mersey, specialist consultancy LDRA ...

Soft centred

Electronic products, particularly in high tech sectors, have become more ...

Hunting noise sources

When integrating a radio chip or module into a typical embedded system, a ...

Gearing up

Many parametric test engineers are learning to cope with new high voltage ...

Numerical computations

This white paper speaks to matters affecting computationally intensive new ...

High temp clock oscillators

Frequency control specialist IQD has unveiled the LHAT range of high ...

SYLOG-USB-2 data logger

Electronic Assembly's SYLOG-USB-2 data logger is designed to monitor and record ...

High voltage SourceMeter

Keithley Instruments has introduced the Model 2657A High Power System ...

2012 Wireless Seminar

14th June 2012, Winnersh, UK

Automated Test Summit

21st June 2012, Royal Berkshire Conference Centre, Madejski Stadium, Reading, UK

SENSORS + SYSTEMS 2012

24-25th october 2012, Silverstone Circuit, Northamptonshire, UK

Bare-die training

Texas Instruments Incorporated has expanded package options with the additional ...

Gas detector demo

Jason demonstrates a nondispersive infrared (NDIR) gas detector sensor ...

Code Composer Studio v5

This video provides a quick introduction to the Code Composer Studio v5 ...

Design reuse

It's become a cliché in news or science reports. A water treatment plant ...

JTAG testing for everyman (and everywoman)

Believe it or not JTAG testing (the original purpose for the now venerable ...

New use for scopes

Bored test and measurement experts have managed to find an alternate and ...

Benoit Neel, vp, Agilent

Graham Pitcher finds out from Agilent how the European test and measurement ...

Trevor Cross, cto, e2v

Graham Pitcher speaks to Trevor Cross about how the new Electronics, Sensors ...

Bill Goldie, md, Retronix

Bill Goldie, managing director of Retronix (Asia) discusses the problem of ...